Vicimeter CM-2007 AC Clamp Meter
CM-2007 28mm clamp open, 800A True RMS, Capacitance Frequency, Temperature, NCV tests, Backlight, Clamp lighting function.
CM-2007 clamp meter, available to DC voltage, AC voltage, AC current, resistance, capacitance, frequency, non-contact voltage, temperature, diode and continuity tests; Designed with unit symbol and backlight display, data hold, clamp lighting, auto ranging switch, auto power and alarm functions.
4000 digits display
CM-2007 Specifications
Technical Data:
Basic function | Range | Accuracy | |
DCV | 400mV/4V/40V/400V/600V | ± (0.5%+5) | |
ACV | 4V/40V/400V/600V | ±(1.0%+5) | |
ACA | 4A/40A/400A/800A | ±(2.0%+5) | |
Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | ±(0.8%+3) | |
Capacitance | 4nF/40nF/400nF/4uF/40uF/400uF/4mF/40mF | ±(2.5%+5) | |
Frequency | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz | ±(0.5%+5) | |
Temperature | -40℃ to 1000℃ | -40 to 1832℉ | ±(1.0%+5) | |
| |||
Model | CM-2007 | ||
NCV, TRMS | √ | ||
Diode test | √ | ||
Continuity alarm | Less than 50 Ω | ||
Low battery indication | Less than 2.4 V | ||
Data hold | √ | ||
Auto power off | Approx. 15minutes | ||
Function protection | √ | ||
Clamp light display | √ | ||
Backlight display | √ | ||
Input impedance | 10MΩ | ||
Sampling rate | 3 times/s | ||
AC frequency response | Current (40 to 1000) Hz, Voltage (40 to 2000) Hz | ||
Operation method | Auto or manual range | ||
Max. display | 4000 | ||
Clamp open | 28mm | ||
Power source | 3V (2pcs #7 batteries) | ||
CM-2007 Product Details


CM-2007 Accessories in the Box

CM-2007 Manual and Downloads
- CM-2007_enDownload