Vicimeter VC88 Auto Range Multimeter
VC88 COMS, TTL logic level tests, Frequency, Duty-cycle, REL, tests, Data hold, Backlight.
VC88 multimeter, available to DC voltage, AC voltage, DC current, AC current, resistance, capacitance, frequency, logic (TTL COMS), temperature, duty-cycle, hFE, Diode and continuity tests; Designed with unit symbol display, data hold, REL test, auto/manual ranging shift, auto power off and alarm functions.
4000 digits display
VC88 Specifications
Technical Data:
Basic function | Range | Accuracy |
DCV | 400mV/4V/40V/400V/1000V | ±(0.5%+5) |
ACV | 4V/40V/400V/750V | ±(0.8%+10) |
DCA | 400uA/4000uA/40mA/400mA/4A/20A | ±(1.0%+5) |
ACA | 400uA/4000uA/40mA/400mA/4A/20A | ±(1.5%+10) |
Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | ±(0.8%+2) |
Capacitance | 40nF/ 400nF/4uF/40uF/400uF/4mF/40mF | ±(2.5%+5) |
Frequency | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz | ±(0.5%+4) |
Temperature | -40℃~1000℃丨-40℉~1832℉ | ±(1.0%+5) |
Special Function:
Model | VC88 |
Logic function | √ |
Diode and hFE test | √ |
Continuity alarm | Less than 50Ω |
Low battery indication | Approx. less than 2.4 V |
Duty cycle test | √ |
Data hold | √ |
Backlight display | √ |
Auto power off | About 15 minutes |
Function protection | √ |
Input impedance | 10MΩ |
Sampling rate | 3times/s |
AC frequency response | 40Hz~2kHz |
Operation method | Auto or manual range |
Max display | 4000 |
LCD size | 54x30mm |
Battery | 3V (1.5V AAA×2) |
Power consumption | Quiescent current approx. 2mA |
VC88 Product Details

VC88 Accessories in the Box

VC88 Manual and Downloads
- VC88_en_manualDownload