VC890C1000V 20A 20MΩ 200μF 1000℃ student use multimeter
VC890C Manual ranging, Max 200uF capacitance, Anti-high pressure ignition design, high-strength anti-drop protection shock-proof holster.
VC890C multimeter, DC voltage, AC voltage, DC current, AC current, Resistance, Capacitance, Temperature, Diode and Contunity tests; Designed with unit symbol, data hold, Auto power off and alarm functions. 2000 digits display.
VC890C Specifications
Technical Data:
Basic function | Range | Basic accuracy |
DCV | 200mV/2V/20V/200V/1000V | ±(0.5%+4) |
ACV | 2V/20V/200V/750V | ±(0.8%+6) |
DCA | 20μA/200uA/2mA/20mA/200mA/20A | ±(1.0%+5) |
ACA | 20μA/200uA/2mA/20mA/200mA/20A | ±(1.5%+5) |
Resistance | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ/200MΩ | ±(0.8%+1) |
Capacitance | 2nF/20nF/200nF/2μF/20μF/200μF | ±(2.5%+5) |
Frequency | 2kHz/200kHz | ±(0.5%+4) |
Temperature | -40℃~1000℃丨-40°F~1832°F | ±(1.0%+5) |
Special Function:
Model | VC890C |
Diode test | √ |
Continuity alarming | Approx. less than 50Ω |
Low battery indication | Approx less than 2.4V |
Data hold | √ |
Function protect | √ |
Anti-shock protect | √ |
Input impendence | 10MΩ |
Sampling rate | 3times/s |
AC Frequency response | 40Hz-2kHz |
Operation way | Manual range |
Max. display | 1999 |
LCD size | 54x30mm |
Battery | 3V(2×1.5V AAA) |
Power consumption | Quiescent current approx. 3mA |
VC890C Product Details

VC890C Accessories in the Box

VC890C Manual and Downloads
- VC890C_en_manualDownload